Dataset Open Access
<?xml version='1.0' encoding='UTF-8'?>
<record xmlns="http://www.loc.gov/MARC21/slim">
<leader>00000nmm##2200000uu#4500</leader>
<datafield tag="540" ind1=" " ind2=" ">
<subfield code="u">https://creativecommons.org/licenses/by/4.0/legalcode</subfield>
<subfield code="a">Creative Commons Attribution 4.0 International</subfield>
</datafield>
<datafield tag="856" ind1="4" ind2=" ">
<subfield code="s">5558</subfield>
<subfield code="u">https://www.fdr.uni-hamburg.de/record/10183/files/example_code.R</subfield>
<subfield code="z">md5:fae8883504804d67e934cf52ccfdd015</subfield>
</datafield>
<datafield tag="856" ind1="4" ind2=" ">
<subfield code="s">1027</subfield>
<subfield code="u">https://www.fdr.uni-hamburg.de/record/10183/files/example_data.csv</subfield>
<subfield code="z">md5:5a0d0f23d5cc1b2c36aabfb1c164bf71</subfield>
</datafield>
<datafield tag="856" ind1="4" ind2=" ">
<subfield code="s">25299</subfield>
<subfield code="u">https://www.fdr.uni-hamburg.de/record/10183/files/localization.csv</subfield>
<subfield code="z">md5:26bc04fe4123065e48369b80ce162096</subfield>
</datafield>
<datafield tag="856" ind1="4" ind2=" ">
<subfield code="s">15459</subfield>
<subfield code="u">https://www.fdr.uni-hamburg.de/record/10183/files/recalibration.csv</subfield>
<subfield code="z">md5:88ed69706e19fda551ce0983012a3f76</subfield>
</datafield>
<datafield tag="041" ind1=" " ind2=" ">
<subfield code="a">eng</subfield>
</datafield>
<datafield tag="909" ind1="C" ind2="O">
<subfield code="o">oai:fdr.uni-hamburg.de:10183</subfield>
<subfield code="p">user-uhh</subfield>
</datafield>
<datafield tag="773" ind1=" " ind2=" ">
<subfield code="a">10.25592/uhhfdm.948</subfield>
<subfield code="i">references</subfield>
<subfield code="n">doi</subfield>
</datafield>
<datafield tag="773" ind1=" " ind2=" ">
<subfield code="a">https://osf.io/xcskn/</subfield>
<subfield code="i">references</subfield>
<subfield code="n">url</subfield>
</datafield>
<datafield tag="773" ind1=" " ind2=" ">
<subfield code="a">10.25592/uhhfdm.10182</subfield>
<subfield code="i">isVersionOf</subfield>
<subfield code="n">doi</subfield>
</datafield>
<controlfield tag="001">10183</controlfield>
<datafield tag="245" ind1=" " ind2=" ">
<subfield code="a">Quantifying accuracy and precision from continuous response data in studies of spatial perception and crossmodal recalibration</subfield>
</datafield>
<datafield tag="100" ind1=" " ind2=" ">
<subfield code="a">Bruns, Patrick</subfield>
<subfield code="u">Universität Hamburg</subfield>
<subfield code="0">(orcid)0000-0002-2977-8874</subfield>
</datafield>
<datafield tag="980" ind1=" " ind2=" ">
<subfield code="a">user-uhh</subfield>
</datafield>
<datafield tag="260" ind1=" " ind2=" ">
<subfield code="c">2022-05-04</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a"><p>This dataset contains data and code&nbsp;associated with the study &quot;Quantifying accuracy and precision from continuous response data in studies of spatial perception and crossmodal recalibration&quot; by Patrick Bruns, Caroline Thun, and Brigitte R&ouml;der.</p>
<p><strong>example_code.R</strong> contains analysis code that can be used to&nbsp;to calculate error-based and regression-based localization performance metrics from single-subject response data with a working example in R. It requires as&nbsp;inputs&nbsp;a numeric vector containing the stimulus location (true value) in each trial and&nbsp;a numeric vector containing the corresponding localization response (perceived value) in each trial.</p>
<p><strong>example_data.csv</strong> contains the data used in the working example of the analysis code.</p>
<p><strong>localization.csv</strong> contains extracted localization performance metrics from 188 subjects which were analyzed in the study to assess the agreement between error-based and regression-based measures of accuracy and precision. The subjects had all naively performed an azimuthal sound localization task (see related identifiers for the underlying raw data).</p>
<p><strong>recalibration.csv</strong> contains extracted localization performance metrics from a subsample of 57 subjects in whom data from a second sound localization test, performed after exposure to audiovisual stimuli in which the visual stimulus was consistently presented 13.5&deg; to the right of the sound source, were available. The file contains baseline performance (pre) and changes in performance after audiovisual exposure&nbsp;relative to baseline (delta) in each of the localization performance metrics.</p>
<p>Localization performance metrics were either derived from the single-trial localization errors (error-based approach) or from a linear regression of localization responses on the actual target locations (regression-based approach).The following localization performance metrics were included in the study:</p>
<p><strong>bias:</strong> overall bias of localization responses to the left (negative values) or to the right (positive values), equivalent to constant error (CE) in error-based approaches and intercept in regression-based approaches</p>
<p><strong>absolute constant error (aCE):</strong> absolute value of bias (or CE), indicates the amount of bias irrespective of direction</p>
<p><strong>mean absolute contant error (maCE):</strong> mean of the aCE per target location, reflects over- or underestimation of peripheral target locations</p>
<p><strong>variable error (VE): </strong>mean of the standard deviations (<em>SD</em>) of the single-trial localization errors at each target location</p>
<p><strong>pooled variable error (pVE):</strong>&nbsp;<em>SD</em> of the single-trial localization errors pooled across trials from all target locations</p>
<p><strong>absolute error (AE):</strong> mean of the absolute values of the single-trial localization errors, sensitive to both bias and variability of the localization responses</p>
<p><strong>slope: </strong>slope of the regression model function, indicates an overestimation (values &gt; 1) or underestimation (values &lt; 1) of peripheral target locations</p>
<p><strong><em>R</em><sup>2</sup>: </strong>coefficient of determination of the regression model, indicates the goodness of the fit of the localization&nbsp;responses to the regression line</p></subfield>
</datafield>
<datafield tag="980" ind1=" " ind2=" ">
<subfield code="a">dataset</subfield>
</datafield>
<datafield tag="542" ind1=" " ind2=" ">
<subfield code="l">open</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="7">
<subfield code="a">cc-by</subfield>
<subfield code="2">opendefinition.org</subfield>
</datafield>
<controlfield tag="005">20240227090459.0</controlfield>
<datafield tag="024" ind1=" " ind2=" ">
<subfield code="a">10.25592/uhhfdm.10183</subfield>
<subfield code="2">doi</subfield>
</datafield>
</record>