Dataset Open Access

Dataset for paper: Extending SiPM Dynamic Range with Non-Linear Response Correction: The Single-Step Method

Antonello, Massimiliano; Brinkmann, Lukas; Freund, Tobias Johannes; Garutti, Erika; Neumann, Katjana; Schwandt, Jörn


JSON Export

{"conceptdoi":"10.25592/uhhfdm.18482","conceptrecid":"18482","created":"2026-03-18T12:48:38.423732+00:00","doi":"10.25592/uhhfdm.18483","id":18483,"links":{"badge":"https://www.fdr.uni-hamburg.de/badge/doi/10.25592/uhhfdm.18483.svg","conceptbadge":"https://www.fdr.uni-hamburg.de/badge/doi/10.25592/uhhfdm.18482.svg","conceptdoi":"http://doi.org/10.25592/uhhfdm.18482","doi":"http://doi.org/10.25592/uhhfdm.18483"},"metadata":{"access_right":"open","access_right_category":"success","communities":[{"id":"uhh"}],"creators":[{"affiliation":"University of Hamburg","name":"Antonello, Massimiliano","orcid":"0000-0001-9094-482X"},{"affiliation":"University of Hamburg","name":"Brinkmann, Lukas","orcid":"0009-0005-0632-2945"},{"affiliation":"University of Hamburg","name":"Freund, Tobias Johannes","orcid":"0009-0003-4084-8305"},{"affiliation":"University of Hamburg","name":"Garutti, Erika","orcid":"0000-0003-0634-5539"},{"affiliation":"University of Hamburg","name":"Neumann, Katjana","orcid":"0009-0006-3220-1634"},{"affiliation":"University of Hamburg","name":"Schwandt, J\u00f6rn","orcid":"0000-0002-0052-597X"}],"description":"<p>Raw measurement data and analysis workflow for the article M. Antonello et al., &quot;Extending SiPM Dynamic Range with Non-Linear Response Correction: The Single-Step Method&quot;, 2025 JINST 20 C08030, https://doi.org/10.1088/1748-0221/20/08/C08030.</p>\n\n<p>The deposit contains the raw HDF5 files from the&nbsp;setup described in the paper, the wheel calibration file, and the complete analysis configuration used to reproduce the published results with SUMLab and Peakotron dedicated software. The full step-by-step workflow is documented in the included README.</p>","doi":"10.25592/uhhfdm.18483","keywords":["SiPM","silicon photomultiplier","dynamic range","non-linear response","single-step method","saturation correction"],"language":"eng","license":{"id":"CC-BY-4.0"},"notes":"The authors acknowledge the support from BMBF via the project 05H24GUB (High-D-Calo). This\nwork is supported by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation)\nunder Germany's Excellence Strategy, EXC 2121, Quantum Universe (390833306).","publication_date":"2025-08-29","related_identifiers":[{"identifier":"10.1088/1748-0221/20/08/C08030","relation":"isSupplementTo","scheme":"doi"},{"identifier":"10.5281/zenodo.19353799","relation":"isSupplementedBy","scheme":"doi"},{"identifier":"10.5281/zenodo.19356653","relation":"isSupplementedBy","scheme":"doi"},{"identifier":"10.25592/uhhfdm.18482","relation":"isVersionOf","scheme":"doi"}],"relations":{"version":[{"count":1,"index":0,"is_last":true,"last_child":{"pid_type":"recid","pid_value":"18483"},"parent":{"pid_type":"recid","pid_value":"18482"}}]},"resource_type":{"title":"Dataset","type":"dataset"},"title":"Dataset for paper: Extending SiPM Dynamic Range with Non-Linear Response Correction: The Single-Step Method","version":"1.0.0"},"owners":[913],"revision":4,"updated":"2026-03-31T17:49:07.118056+00:00"}

Cite record as