Dataset Open Access

Dataset for paper: Extending SiPM Dynamic Range with Non-Linear Response Correction: The Single-Step Method

Antonello, Massimiliano; Brinkmann, Lukas; Freund, Tobias Johannes; Garutti, Erika; Neumann, Katjana; Schwandt, Jörn


JSON-LD (schema.org) Export

{"@context":"https://schema.org/","@id":"http://doi.org/10.25592/uhhfdm.18483","@type":"Dataset","creator":[{"@id":"https://orcid.org/0000-0001-9094-482X","@type":"Person","affiliation":"University of Hamburg","name":"Antonello, Massimiliano"},{"@id":"https://orcid.org/0009-0005-0632-2945","@type":"Person","affiliation":"University of Hamburg","name":"Brinkmann, Lukas"},{"@id":"https://orcid.org/0009-0003-4084-8305","@type":"Person","affiliation":"University of Hamburg","name":"Freund, Tobias Johannes"},{"@id":"https://orcid.org/0000-0003-0634-5539","@type":"Person","affiliation":"University of Hamburg","name":"Garutti, Erika"},{"@id":"https://orcid.org/0009-0006-3220-1634","@type":"Person","affiliation":"University of Hamburg","name":"Neumann, Katjana"},{"@id":"https://orcid.org/0000-0002-0052-597X","@type":"Person","affiliation":"University of Hamburg","name":"Schwandt, J\u00f6rn"}],"datePublished":"2025-08-29","description":"<p>Raw measurement data and analysis workflow for the article M. Antonello et al., &quot;Extending SiPM Dynamic Range with Non-Linear Response Correction: The Single-Step Method&quot;, 2025 JINST 20 C08030, https://doi.org/10.1088/1748-0221/20/08/C08030.</p>\n\n<p>The deposit contains the raw HDF5 files from the&nbsp;setup described in the paper, the wheel calibration file, and the complete analysis configuration used to reproduce the published results with SUMLab and Peakotron dedicated software. The full step-by-step workflow is documented in the included README.</p>","distribution":[{"@type":"DataDownload","contentUrl":"https://www.fdr.uni-hamburg.de/api/files/52400970-5afc-44b3-b439-8dee8bb80027/corner_2024-12-13_12-38-03_KetekPM1125S1W1_T20_V5.h5","encodingFormat":"h5"},{"@type":"DataDownload","contentUrl":"https://www.fdr.uni-hamburg.de/api/files/52400970-5afc-44b3-b439-8dee8bb80027/matrix_2024-12-16_12-26-19_KetekPM1125S1W1_T20_-20_V-3_-5.h5","encodingFormat":"h5"},{"@type":"DataDownload","contentUrl":"https://www.fdr.uni-hamburg.de/api/files/52400970-5afc-44b3-b439-8dee8bb80027/README.pdf","encodingFormat":"pdf"},{"@type":"DataDownload","contentUrl":"https://www.fdr.uni-hamburg.de/api/files/52400970-5afc-44b3-b439-8dee8bb80027/tredi25_conlis_correction_KetekPM1125S1W1_T20_Vov_5.joblib","encodingFormat":"joblib"},{"@type":"DataDownload","contentUrl":"https://www.fdr.uni-hamburg.de/api/files/52400970-5afc-44b3-b439-8dee8bb80027/tredi25_conlis_correction_KetekPM1125S1W1_T20_Vov_5_minus_err.joblib","encodingFormat":"joblib"},{"@type":"DataDownload","contentUrl":"https://www.fdr.uni-hamburg.de/api/files/52400970-5afc-44b3-b439-8dee8bb80027/tredi25_conlis_correction_KetekPM1125S1W1_T20_Vov_5_plus_err.joblib","encodingFormat":"joblib"},{"@type":"DataDownload","contentUrl":"https://www.fdr.uni-hamburg.de/api/files/52400970-5afc-44b3-b439-8dee8bb80027/wheel_attenuation_data.dat","encodingFormat":"dat"}],"identifier":"http://doi.org/10.25592/uhhfdm.18483","inLanguage":{"@type":"Language","alternateName":"eng","name":"English"},"keywords":["SiPM","silicon photomultiplier","dynamic range","non-linear response","single-step method","saturation correction"],"license":"https://creativecommons.org/licenses/by/4.0/legalcode","name":"Dataset for paper: Extending SiPM Dynamic Range with Non-Linear Response Correction: The Single-Step Method","url":"https://www.fdr.uni-hamburg.de/record/18483","version":"1.0.0"}

Cite record as